facade2026-03-23·9 min read

Architect Specification Guide for Alcodec Outdoor Systems

Specification writing guide for architects. CSI MasterFormat, performance criteria, CAD details and BIM objects for Alcodec systems.

Architect Specification Guide for Alcodec Outdoor Systems

CSI MasterFormat Specification\n\nAlcodec outdoor systems are specified under MasterFormat Division 10 (Specialties) Section 10 73 00 (Protective Covers) for pergola and canopy systems, and Division 05 (Metals) Section 05 73 00 (Decorative Metal Railings) for glass railing systems. The three-part specification format includes Part 1: General (scope, references, submittals, quality assurance), Part 2: Products (materials, fabrication, finishes), and Part 3: Execution (installation, adjustment, cleaning). Alcodec provides pre-written specification sections that architects can adapt for project-specific requirements.\n\n## Performance Specification Criteria\n\nPerformance-based specifications define required outcomes rather than prescriptive material selections. Key performance criteria include: wind load resistance (specify design wind pressure in kN/m2 per EN 1991-1-4), snow load capacity (specify characteristic snow load per EN 1991-1-3), thermal performance (specify maximum U-value for glazed elements), acoustic performance (specify minimum Rw rating), and fire classification (specify minimum EN 13501-1 rating). Alcodec systems meet or exceed standard performance requirements for European installations.\n\n## CAD Detail Library\n\nAlcodec provides a comprehensive CAD detail library for integration into architectural drawings. Standard details include foundation connections (pad, strip, and pile options), wall interface details (face-fix, concealed bracket, and cantilever options), drainage integration (internal gutter, external gutter, and chain drainage), electrical routing (concealed cable paths for motors, lighting, and sensors), and glass railing base channel sections. All details are available in DWG, DXF, and PDF formats.\n\n## BIM Object Library\n\nRevit families are available for all Alcodec product ranges at LOD 300 (design development) and LOD 400 (construction documentation) detail levels. IFC format objects ensure compatibility with other BIM platforms including ArchiCAD, Vectorworks, and Allplan. Objects include parametric dimensions, material specifications, and embedded manufacturer data. The BIM library is updated quarterly to reflect current product specifications and new product releases.

Explore our products or get in touch.

Related Articles

facade

Zip Screen Guide: Wind-Resistant Exterior Blinds for Every Facade

facade

Brise Soleil Guide: How to Reduce Solar Heat Gain on High-Rise Facades

facade

Energy Performance of External Shading: How to Reduce Cooling Loads 30-40%