Materials
- Material
- Aluminium posts + between-post VSG Glass
- Post Dimensions
- Glass panel between aluminium posts
- Recyclable
- 98%
MODEL SELECTION
For post glass railing, the key decision is the post-glass relationship: rear-post, between-post or handrail-supported.
Compare the models in this product group side by side; each card opens its product page.
Final selection is confirmed by glass thickness, fixing surface, anchors and project loads.

Glass panels held between aluminium posts

Cleaner glass face from outside

A more defined railing line with top handrail
Glass panels held between aluminium posts
Between-post glass railing carries each glass panel between aluminium posts, giving balconies and stair edges a clear modular rhythm.

TECHNICAL PROFILE
Read the system character first, then confirm material, glass or infill, top fixing, fascia or side fixing, anchors and performance data together.
Material
Aluminium posts + between-post VSG Glass
Glass Thickness
VSG review route
Mounting
Balcony edge / sill review
ALR-GL-VSG66 / ALR-GL-VSG88 / ALR-GL-VSG1010
Code route
ALR-GL-VSG66
6+6 mm VSG laminated glass route
Code route
ALR-GL-VSG88
8+8 mm VSG laminated glass route
Code route
ALR-GL-VSG1010
10+10 mm VSG laminated glass route
ALR-ANC-M12-CHM / ALR-ANC-A4-SS
Code route
ALR-ANC-M12-CHM
M12 chemical anchor route
Code route
ALR-ANC-A4-SS
A4 stainless anchor / fixing part
System code
ALR-PGB-BP
Code route
ALR-PGB-BP
Between-post glass railing
Post codes
ALR-PST-SQ4040 / ALR-PST-RE5025 / ALR-PST-RD50
Code route
ALR-PST-SQ4040
40x40 square post
Code route
ALR-PST-RE5025
50x25 rectangular post
Code route
ALR-PST-RD50
Ø50 round post
Clamp codes
ALR-CLP-SQ / ALR-CLP-RD
Code route
ALR-CLP-SQ
Square glass clamp
Code route
ALR-CLP-RD
Round glass clamp
Adjustment codes
ALR-ADJ-EPDM
Code route
ALR-ADJ-EPDM
EPDM gasket and glass bedding
Market terms
Between-post glass railing places each glass panel between aluminium posts. The result is a visible modular rhythm on the facade, useful for residential balconies, stair edges, atrium edges and projects with controlled bay spacing.
Post section, clamp type, glass clearance, handrail need, panel width and centre-to-centre spacing should be reviewed before quotation. The glass build-up is selected from VSG laminated safety glass according to project loads and local approval expectations.
This route works where a fully frameless line is not required but transparency still matters. It creates a middle architectural language between aluminium bar railing and continuous base-channel glass railing.
PRODUCT DECISION GUIDE
Use this product when dimensions, fixing conditions, intended use and technical expectations are clear enough to move into quotation.
Combines safety and transparency for balconies, terraces and commercial edges.
Confirm substrate, anchors, glass height, line load and local standard expectations.
Use railing analyzer and engineering check before locking the product class.
Continue project review
Pre-check glass railing system and glass thickness.
Engineering CheckClarify dimensions, substrate, wind exposure and use case before pricing.
Market routesConnect this product family to country, project-type and buyer-intent landing pages.
Product finderCompare alternative systems against the same project need.
Project reviewClarify dimensions, substrate, wind exposure and use case before pricing.
PRODUCT ANSWERS
Use these notes to check the product against project data before opening calculators, product finder or smart quote.
For railing, fence and safety products, the first decision is driven by load case, glass or infill type, privacy target, fixing surface, height and the standard expectations in the project country.
Open railing analyzer →Share project country, dimensions, quantity, fixing surface, exposure, finish target and any accessory or documentation need so the first quotation can start with the right technical scope.
Start smart quote →Compare it by use case first, then by control method, structural conditions, finish, service access and whether the project needs dealer, export or engineering support.
Use product finder →ALCODEC
Frameless Glass — 100mm Slim Base Shoe
Frameless glass balustrade — EN 1991-1-1 compliant, panoramic views
One Frame, Any Infill — MARS System
Modular aluminium balcony railing — bars, glass or perforated infill options
35mm Projection — WDVS Compatible
Flush-mount French balcony — VSG safety glass, no window frame drilling
Balcony, service-balcony and facade repetition context from Tempo City Kağıthane

Residential balcony and facade routes with rear-post glass, horizontal service-balcony profiles and coordinated aluminium finishes.

Useful where glass, post spacing and horizontal profiles must stay coordinated around ventilation and maintenance access.

A repeatable product route for multi-unit facades where the same post, glass and colour logic must be applied across many balcony openings.
Calculate the right system, glass thickness and compliance for your project — free engineering pre-analysis.
Configure this product online in 3D — set dimensions, colour, accessories and get an instant quote.
APPLICATIONS

Post-supported glass railing for apartments, terraces and facade balcony lines where the fixing route should remain visible and serviceable.

Horizontal balcony and air-conditioner profile zones can be coordinated with rear posts, ventilation clearances and facade rhythm.

A practical glass guard route for dense residential facades where post spacing, colour and glass height must align with the architecture.
COLOURS & FINISHES
RAL 7016
RAL 9005
RAL 9010
RAL 7035
RAL 8014
RAL 9006
RAL 3004
RAL 6005
TIGER Coatings QUALICOAT · 450+ RAL · catalog.visioAir.finishes
Alcodec VisioAir Post Glass Balustrade
Compare Alcodec glass railing systems for your project
| Specification | Alcodec FS 1500 | Alcodec FS 3000 | Alcodec FS 7000 | Alcodec Square Spigot Glass Railing | Alcodec VisioAir Post Glass Balustrade |
|---|---|---|---|---|---|
| Material | Aluminium + VSG Glass | Aluminium + VSG Glass | Aluminium + VSG Glass | Aluminium spigot + VSG Glass | Aluminium posts + VSG Glass |
| System Code | ALR-FS15-BZA | ALR-FS30-BZA | ALR-FS70-HDB | ALR-SPQ-GL / ALR-SPR-GL | ALR-PGR-RP / ALR-PGB-BP / ALR-PGH-HR |
| Glass Codes | ALR-GL-VSG88 / ALR-GL-VSG1010 route | ALR-GL-VSG1010 / ALR-GL-VSG1212 route | ALR-GL-VSG1212 / ALR-GL-VSG1515 route | ALR-GL-VSG66 / ALR-GL-VSG88 | ALR-GL-VSG66 / ALR-GL-VSG88 / ALR-GL-VSG1010 |
| Mounting Codes | ALR-MNT-TOP / YAN / KNR | ALR-MNT-TOP / YAN / GZL / KNR | ALR-MNT-TOP / YAN / GZL / KNR | ALR-MNT-TOP | — |
| Anchor Codes | ALR-ANC-M12-CHM / ALR-ANC-A4-SS | ALR-ANC-M16-CHM / ALR-ANC-A4-SS | ALR-ANC-M16-CHM / ALR-ANC-A4-SS | ALR-ANC-M12-CHM / ALR-ANC-A4-SS | ALR-ANC-M12-CHM / ALR-ANC-A4-SS |
| Adjustment Codes | ALR-ADJ-EPDM / KAMA / DREN | ALR-ADJ-EPDM / KAMA / DREN | ALR-ADJ-EPDM / KAMA / DREN | ALR-ADJ-EPDM | ALR-ADJ-EPDM |
| Glass Thickness | 8+8mm / 10+10mm VSG review route | 10+10mm / 12+12mm VSG review route | 12+12mm / 15+15mm VSG project route | 6+6mm / 8+8mm VSG review route | 2×8mm VSG route |
| Wind Load | 1.5 kPa review route | 3.0 kPa review route | 7.0 kPa review route | — | — |
| Recyclable | 98% | 98% | 98% | 98% | 98% |
| Certification | EN 1991-1-1 / EN 12150 / EN ISO 12543 review route | EN 1991-1-1 / EN 12150 / EN ISO 12543 review route | EN 1991-1-1 / EN 12150 / EN ISO 12543 review route | EN 12150 / EN ISO 12543 review route | EN 1991-1-1 / EN 12150 / EN ISO 12543 review route |
| Mounting | — | — | — | Square or round spigot on verified sill | Facade, sill or balcony edge review |
| Application | — | — | — | Private villa balcony | Urban residential balconies and service-balcony screens |
| Posts | — | — | — | — | Rear post, between-post or handrail-supported route |
| Profile Use | — | — | — | — | Horizontal service-balcony and air-conditioner balcony profiles |