Suitable projects
Combines safety and transparency for balconies, terraces and commercial edges.
- Balconies and terraces
- Commercial edge safety
- View-preserving glass
Rear-post glass for balconies and service-balcony profiles
Post-supported glass railing for urban residential balconies, air-conditioner balcony screens and facade edges where a rear/post route is more suitable than a continuous base channel.

SYSTEM OPTIONS
For post glass railing, the key decision is where the post holds the glass: front, rear or side. These options show different application routes within the same product family.

Visible post rhythm on the facade

Cleaner glass face from outside

For edge and side-mounted conditions
Final selection is confirmed by glass thickness, fixing surface, anchors and project loads.
Technical Specifications
Material
Aluminium rear posts + VSG Glass
System code
ALR-PGR-RP
Glass codes
ALR-GL-VSG66 / ALR-GL-VSG88 / ALR-GL-VSG1010
Anchor codes
ALR-ANC-M12-CHM / ALR-ANC-A4-SS
Post Dimensions
Rear post behind glass route
Glass Thickness
VSG review route
Mounting
Parapet / balcony edge review
application
Cleaner outside glass face
Recyclable
98%
VisioAir is the post-supported glass railing route for balconies, service-balcony profiles and facade edges where a continuous base channel is not the preferred detail. The system combines aluminium posts with laminated safety glass and is reviewed around the substrate, balcony edge, fixing route, wind exposure and local approval path. The Tempo City Kağıthane reference context shows the typical use case: residential balcony lines, horizontal service-balcony profiles and rear-post glass screens on a dense urban facade.
PRODUCT DECISION GUIDE
Use this product when dimensions, fixing conditions, intended use and technical expectations are clear enough to move into quotation.
Combines safety and transparency for balconies, terraces and commercial edges.
Confirm substrate, anchors, glass height, line load and local standard expectations.
Use railing analyzer and engineering check before locking the product class.
Continue project review
Pre-check glass railing system and glass thickness.
Engineering CheckClarify dimensions, substrate, wind exposure and use case before pricing.
Market routesConnect this product family to country, project-type and buyer-intent landing pages.
Product finderCompare alternative systems against the same project need.
Project reviewClarify dimensions, substrate, wind exposure and use case before pricing.
PRODUCT ANSWERS
Use these notes to check the product against project data before opening calculators, product finder or smart quote.
For railing, fence and safety products, the first decision is driven by load case, glass or infill type, privacy target, fixing surface, height and the standard expectations in the project country.
Open railing analyzer →Share project country, dimensions, quantity, fixing surface, exposure, finish target and any accessory or documentation need so the first quotation can start with the right technical scope.
Start smart quote →Compare it by use case first, then by control method, structural conditions, finish, service access and whether the project needs dealer, export or engineering support.
Use product finder →ALCODEC
Frameless Glass — 100mm Slim Base Shoe
Frameless glass balustrade — EN 1991-1-1 compliant, panoramic views
One Frame, Any Infill — MARS System
Modular aluminium balcony railing — bars, glass or perforated infill options
35mm Projection — WDVS Compatible
Flush-mount French balcony — VSG safety glass, no window frame drilling
Balcony, service-balcony and facade repetition context from Tempo City Kağıthane

Residential balcony and facade routes with rear-post glass, horizontal service-balcony profiles and coordinated aluminium finishes.

Useful where glass, post spacing and horizontal profiles must stay coordinated around ventilation and maintenance access.

A repeatable product route for multi-unit facades where the same post, glass and colour logic must be applied across many balcony openings.
Calculate the right system, glass thickness and compliance for your project — free engineering pre-analysis.
Configure this product online in 3D — set dimensions, colour, accessories and get an instant quote.
APPLICATIONS

Post-supported glass railing for apartments, terraces and facade balcony lines where the fixing route should remain visible and serviceable.

Horizontal balcony and air-conditioner profile zones can be coordinated with rear posts, ventilation clearances and facade rhythm.

A practical glass guard route for dense residential facades where post spacing, colour and glass height must align with the architecture.
COLOURS & FINISHES
RAL 7016
RAL 9005
RAL 9010
RAL 7035
RAL 8014
RAL 9006
RAL 3004
RAL 6005
TIGER Coatings QUALICOAT · 450+ RAL · catalog.visioAir.finishes
Alcodec VisioAir Post Glass Balustrade
Compare Alcodec glass railing systems for your project
| Specification | Alcodec FS 1500 | Alcodec FS 3000 | Alcodec FS 7000 | Alcodec Square Spigot Glass Railing | Alcodec VisioAir Post Glass Balustrade |
|---|---|---|---|---|---|
| Material | Aluminium + VSG Glass | Aluminium + VSG Glass | Aluminium + VSG Glass | Aluminium spigot + VSG Glass | Aluminium posts + VSG Glass |
| System Code | ALR-FS15-BZA | ALR-FS30-BZA | ALR-FS70-HDB | ALR-SPQ-GL / ALR-SPR-GL | ALR-PGF-FP / ALR-PGR-RP / ALR-PGS-SM |
| Glass Codes | ALR-GL-VSG88 / ALR-GL-VSG1010 route | ALR-GL-VSG1010 / ALR-GL-VSG1212 route | ALR-GL-VSG1212 / ALR-GL-VSG1515 route | ALR-GL-VSG66 / ALR-GL-VSG88 | ALR-GL-VSG66 / ALR-GL-VSG88 / ALR-GL-VSG1010 |
| Mounting Codes | ALR-MNT-TOP / YAN / KNR | ALR-MNT-TOP / YAN / GZL / KNR | ALR-MNT-TOP / YAN / GZL / KNR | ALR-MNT-TOP | — |
| Anchor Codes | ALR-ANC-M12-CHM / ALR-ANC-A4-SS | ALR-ANC-M16-CHM / ALR-ANC-A4-SS | ALR-ANC-M16-CHM / ALR-ANC-A4-SS | ALR-ANC-M12-CHM / ALR-ANC-A4-SS | ALR-ANC-M12-CHM / ALR-ANC-A4-SS |
| Adjustment Codes | ALR-ADJ-EPDM / KAMA / DREN | ALR-ADJ-EPDM / KAMA / DREN | ALR-ADJ-EPDM / KAMA / DREN | ALR-ADJ-EPDM | ALR-ADJ-EPDM |
| Glass Thickness | 8+8mm / 10+10mm VSG review route | 10+10mm / 12+12mm VSG review route | 12+12mm / 15+15mm VSG project route | 6+6mm / 8+8mm VSG review route | 2×8mm VSG route |
| Wind Load | 1.5 kPa review route | 3.0 kPa review route | 7.0 kPa review route | — | — |
| Recyclable | 98% | 98% | 98% | 98% | 98% |
| Certification | EN 1991-1-1 / EN 12150 / EN ISO 12543 review route | EN 1991-1-1 / EN 12150 / EN ISO 12543 review route | EN 1991-1-1 / EN 12150 / EN ISO 12543 review route | EN 12150 / EN ISO 12543 review route | EN 1991-1-1 / EN 12150 / EN ISO 12543 review route |
| Mounting | — | — | — | Square or round spigot on verified sill | Facade, sill or balcony edge review |
| Application | — | — | — | Private villa balcony | Urban residential balconies and service-balcony screens |
| Posts | — | — | — | — | Rear/post-supported balcony route |
| Profile Use | — | — | — | — | Horizontal service-balcony and air-conditioner balcony profiles |